CONTENT | ![]() |
Other
1. eDY-Explosion-proof Meters BDY-Explosion-proof Meters
Explosion-proof IMeters
Features May use tubes or cables to connect it. |
![]() |
Specification: 1. Rated voltage: AC 220, 380V DC 6, 12, 24, 36, 48, 110, 220 2. Ex-mark: eIIT6, dIIBT6, dIICT6 3. Protective-class: IP54, IP65 4. Erosion-proof-class: W, WF1, WF2 5. Inlet size: G20,G25 6. Cable dia.: φ8~φ18 |
2.BBK-Explosion-proof Transformers
Features The enclosure is made of casting aluminum alloy, the surfaces are sprayed with plastics, and it may prevent erosions. May be used as the power source of safety for controlling equipment, lighting and signal. The inlet, the transformer, the outlet and the fuse enclosure are independent, so it is very safe. May use tubes or cables to connect it. |
![]() |
Specification: 1. Primary voltage: 220, 380V 2. Second voltage: 6.3, 12, 24, 36, 127V 3. Primary power: 0.1, 0.25, 0.3, 0.4, 0.5, 1, 1.5, 2KVA 4. Ex-mark: dIIBT6 5. Protective-class: IP54, IP65 6. Erosion-proof-class: W, WF1, WF2 7. Inlet size: G20 8. Cable dia.: φ8~φ15 |
3. CBK-Explosion-proof Transformers
Features The enclosure is made of casting aluminum alloy, the surfaces are sprayed with plastics, and it may prevent erosions. May be used as the power source of safety for controlling equipment, lighting and signal. The inlet, the transformer, the outlet and the fuse enclosure are independent, so it is very safe. May use tubes or cables to connect it. |
![]() |
Specification: 1. Primary voltage: 220, 380V 2. Second voltage: 6.3, 12, 24, 36, 127V 3. Primary power: 0.1, 0.25, 0.3, 0.4, 0.5, 1, 1.5, 2KVA 4. Ex-mark: dIICT6 5. Protective-class: IP54, IP65 6. Erosion-proof-class: W, WF1, WF2 7. Inlet size: G20 8. Cable dia.: φ8~φ15 |
4. BDL-125 Explosion-proof Electrical Bells
CDL-125 Explosion-proof Electrical Bells
Features May use tubes or cables to connect it. |
![]() |
Specification: 1. Rated voltage: AC 220V DC 36, 110, 220 2. Sound intensity: ≥75dB(R=2m) 3. Power: ≤20W 4. Ex-mark: dIIBT6, dIICT6 5. Protective-class: IP54, IP65 6. Erosion-proof-class: W, WF1, WF2 7. Inlet size: G20 8. Cable dia.: φ8~φ15 |
5. BDD-220 Explosion-proof Electrical Whistle
The enclosure is made of casting aluminum alloy, the surfaces are sprayed with plastics, it may prevent erosions. May use tubes or cables to connect it. |
![]() |
Specification: 1. Rated voltage: 220V 2. Power: <40VA 3. Sound intensity: >90dB(R=1m) 4. Continuous electrifying time: 5min 5. Ex-mark: dIIBT6, dIICT6 6. Protective-class: IP54, IP65 7. Erosion-proof-class: W, WF1, WF2 8. Inlet size: G20 9. Cable dia.: φ8~φ15 |
6. BZC-Explosion-proof Braking Electromagnet
![]() |
Features |
Specification
Type | Apparent power (VA) |
Actual consumed power (W) |
Attracting force (Kg) |
Rated stroke (mm) |
|
Attracting instant |
Armature continuously attracting |
||||
BZC-6 | 2700 | 330 | 70 | 6 | 20 |
BZC-15 | 14000 | 750 | 150 | 15 | 50 |
Ex-mark | Protective-class | Erosion-proof-class | Inlet size | Cable dia (mm) |
dIIBT6 | IP54, IP65 | W, WF1, WF2 | G25 | φ10~φ18 |
7. BDR-Explosion-proof Electrical Heater
Features May be used for oil box, water box, reaction tower, tank to heat. The enclosure is made of casting aluminum alloy, the surfaces are sprayed with plastics. Heating tube is made of stainless steel tube. It may prevent erosions. May use tubes or cables to connect it. |
![]() |
Specification: 1. Rated voltage: 220, 380V 2. Power: 0.5~15KW 3. Ex-mark: dIIBT4 4. Protective-class: IP54, IP65 5. Erosion-proof-class: W, WF1, WF2 6. Inlet size: G20 7. Cable dia.: φ8~φ15 |
8. SGB-Explosion-proof Flashlights
1. Range: 150m 2. Ex-mark: eiaIIBT6 3. Protective-class: IP54, IP65 |
|
|
![]() |
||
SGB-4A(IP65) | SGB-3A(IP65) | SGB-3B | ||
![]() |
![]() |
![]() |
||
SGB-3C | SGB-3D | SGB-2E |
![]() |
SGD-□F is chargeable explosion-proof flashlight. SGD-□J is chargeable explosion-proof flashlight with flashing. Battery: 2, 3, 4 Recharge voltage: AC220V Recharge place: Safety place Rated voltage: DC2.4V,3.6V,4.8V Rated current: ≤250mA |
SGB-□F SGB-□J |
9. BPG-Frequency Converting Board for Controlling Motor
Features May change the rotational speed of general three-phase asynchronous motor by means of changing output frequency, so that achieve the request of processing technology and saving electric energy up to 30%~60%. May be used as soft starting controller for motor. May be used in closed circuit of adjusting speed system by controlled circuit of some sensor and speed adjustor. Mounting and operating is very easy. Starting is smooth and steady, without current shocks (soft starting). The power source capacity could be greatly decreased. The power factor is constant (COSφ≈1). It has failure indicating and other protecting functions. Because the key part of the frequency converting board is micro-computer, so it has many functions: 1. Protection of over-current, short circuit, over-voltage, under-voltage, instant cutting off power and breaking phase. 2. May display in digital or needle to frequency, rotational speed, load, current etc. 3. May adjust frequency by hand. May set up processing technology curve of rotational speed by time changing. May output signal by DCS system to control frequency. The frequency converter may be selected FUJI or SANKEN or by user. Inside there are some ammeter, voltmeter, circuit breaker, pilot lamp, AC contactor, switch of normal or converting frequency, starting and topping buttons etc. The electric principle, choosing frequency converter and every operating mode may be designed by user's requirement. |
![]() |
Specification: 1. Motor power: 4.5, 7.5, 12, 15, 24, 30, 45, 70KW 2. Input voltage: 380V, 3phase, 50Hz 3. Output voltage: is direct ratio to frequency, max. 380V 4. Output frequency: 2.4~50 or 80, 100, 180Hz |